Capabilities

What EnergyFlow can model

EnergyFlow helps you compare building and equipment choices under the same weather, comfort and usage assumptions. The result is an estimate for the configuration you describe.

Start with the house

Enter your house manually: floors, dimensions, construction year, glazing by outside face, orientation and shading. Construction-year defaults provide starting U-values that you can review and change. CPE and plan uploads are not available in this release.

Compare systems

  • Heating and supported cooling systems, with building temperature and energy results.
  • PV, battery and grid flows using the selected configuration and tariff assumptions.
  • EV charging and modeled V2H behavior where the configuration and package support it.
  • Indoor and outdoor pool cases, which use different models and inputs.

See the boundaries

The model uses floor-level zones. It does not reproduce every room, air current, installation detail or controller. Each feature page explains the inputs, outputs and practical limits.

Capability inventory

CapabilityInputsOutputsCurrent availability
Building and envelopeManual floors, dimensions, construction year, U-values, glazing by face, orientation and shading.Modeled zone temperatures, annual heat and energy results.Manual entry in the current wizard. CPE and plan uploads are not available.
Heating and distributionAir-source or ground-source heat pump, polyvalent 4-pipe, boiler, or electric resistance. UFH or low/high-temperature radiators.Heating demand, equipment energy and modeled zone temperatures.Options exposed by the equipment wizard, subject to configuration rules.
CoolingNone, floor cooling, floor plus AC backup, or AC only, subject to emitter and heat-source requirements.Cooling demand, equipment electricity and modeled temperatures.Options exposed by the equipment wizard; floor cooling includes a modeled dew-point guard.
Hot water and ventilationHeat pump water heater, electric resistance or buffer preheat for DHW; MVHR, extract-only or natural ventilation.Hot-water energy, tank and backup demand, ventilation heat recovery and fan electricity.Options exposed by the equipment wizard. The model uses the configured tank setpoint; no periodic hygiene reheat is simulated.
PV, battery and tariffEast/west or single-orientation PV, battery size, fixed tariff, or dynamic day-ahead prices for your country.PV production, battery charge/discharge, imports, exports and operating cost.Options exposed by the equipment wizard.
EV, V2H and poolEV schedule and charging mode; V2H when configured. Indoor, heated outdoor or unheated outdoor pool cases.EV charging and discharge, pool energy, auxiliary electricity and zone interactions.Pool and EV/V2H are included in both paid plans. See pricing for report and comparison access.
Solar thermalNo solar-thermal collector choice is exposed in the current equipment wizard.Not included as a customer-selectable result in this release.Unavailable in the current public wizard.
Results and downloadsOne saved run's resolved building, weather, equipment, schedule and tariff inputs.Annual KPIs, monthly charts, daily balance, hourly chart and hourly CSV.Paid plans include detailed results and PDF reports. Full Project includes comparison and hourly CSV export. Single House includes one chosen PDF, with no comparison or CSV. See pricing for what each plan includes.