Glossary
The abbreviations and terms you meet in the wizard, the results and this library, in alphabetical order. Each entry is short. Where an article explains the idea properly, the entry links to it.
Abbreviations
| Term | Meaning |
|---|---|
| A7/W35 | A test point for a heat pump: outdoor air (A) at 7 °C, water (W) leaving the heat pump at 35 °C. A35/W18 is the cooling equivalent. See COP and SCOP. |
| AC | Air conditioning. In EnergyFlow, split units that cool the room air. |
| COP | Coefficient of performance: heat delivered divided by the electricity used, at one moment. See COP and SCOP. |
| DHW | Domestic hot water, the hot water for showers, baths and taps. See hot water. |
| EER | Energy efficiency ratio: heat removed in cooling divided by the electricity used, at one moment. See EER and SEER. |
| EMS | Energy management system, the controller that decides where electricity goes each hour: house, battery, car or grid. See what an energy management system changes. |
| EPEX | The European power exchange whose day-ahead auction sets the hourly wholesale prices behind a dynamic tariff. |
| ERA5 | A reanalysis of past weather from ECMWF, the source of the real weather years. See weather. |
| EV | Electric vehicle, an electric car. |
| kWh | Kilowatt-hour, a quantity of energy. Your electricity bill counts kWh. |
| kW | Kilowatt, a rate of power. A 10 kW heat pump can deliver 10 kWh of heat in one hour at full output. |
| kWp | Kilowatt-peak, the rated output of solar panels under standard test conditions. “A 6 kWp array” on a quote. See PV size and roof directions. |
| MVHR | Mechanical ventilation with heat recovery: two fans and a heat exchanger that warm incoming fresh air with the heat of the outgoing stale air. See ventilation. |
| n50 | Airtightness: how many times per hour the air in the house is replaced when a blower-door test holds it at 50 Pa. Lower is tighter. |
| P4P | Four-pipe heat pump. It heats and cools at the same time, and moves the heat it takes out of the house during cooling into the hot circuit, for example the pool or the hot water. |
| PV | Photovoltaic, solar panels that make electricity. |
| SCOP | Seasonal coefficient of performance, the COP averaged over a heating season under standard conditions. See COP and SCOP. |
| SEER | Seasonal energy efficiency ratio, the EER averaged over a cooling season. See EER and SEER. |
| TMY | Typical meteorological year, a year assembled from the most ordinary months of many real years. See weather. |
| V2H | Vehicle-to-home: a parked electric car powers the house through a bidirectional charger. See the methodology article. |
Terms
| Term | Meaning |
|---|---|
| Backup heater | An electric heater in the heating circuit that helps the heat pump on the coldest days. See the backup heater. |
| Day-ahead price | The wholesale price for each hour of tomorrow, set in an auction the day before. |
| Dew point | The temperature at which moisture in the air condenses on a cold surface. It limits how cold a cooling floor may get. See floor cooling and condensation. |
| Dynamic tariff | An electricity price that changes every hour with the wholesale market, instead of one fixed price. |
| Envelope | The shell of the house: walls, roof, floor and windows. |
| g-value | The share of the sun’s heat that glass lets through. |
| Round-trip efficiency | The share of the energy put into a battery that comes back out. |
| Self-consumption | The share of your solar production used in the house, directly or through a battery. See self-consumption and self-sufficiency. |
| Self-sufficiency | The share of your consumption covered by your own solar production. See self-consumption and self-sufficiency. |
| Setpoint | The temperature the heating or cooling tries to hold. |
| State of charge | How full a battery is, as a share of its usable capacity. |
| Thermal mass | The heat the materials of a house can store. See thermal mass. |
| Thermal zone | A part of the house the model treats as one body of air with one temperature. In EnergyFlow each floor is a zone. See the house model. |
| U-value | How much heat passes through one square metre of a wall, roof, floor or window for each degree of difference between inside and outside. Lower is better insulated. |
| Weather compensation | A control that lowers the heating water temperature on milder days, so the heat pump works more efficiently. See floor heating, radiators and weather compensation. |